+353 1 2300733

multi_NC_2100

Multi N/C Series

Highly efficient Multi N/C Series – TOC/TNb Analysers for fast, reliable environmental and industrial analysis.

Product Overview

The multi N/C Series from Analytik Jena offers a comprehensive range of TOC/TNb Analysers, designed for fast and reliable analysis. With options for high-temperature combustion and UV digestion, these analysers provide versatile solutions for various sectors, including environmental, pharmaceutical, oil & gas, and more. The series includes specialised models like multi N/C 2100S, 3100, and UV HS, each tailored to specific analytical needs.

Features & Benefits

multi_NC_2100

High-Temperature Combustion

Complete Oxidation

Direct Injection TOC Analysis

multi N/C 2100S Handle any sample

10-year Warranty

Long-Term Reliability

Key applications of Multi N/C Series

  • High Sensitivity TOC Analysis: Focus Radiation NDIR Detector ensures precise measurements.
  • Direct Injection: an option for the most heavy and difficult matrices
  • Stable Calibration: VITA Flow Management System for consistent results.
  • Versatility: Different models for direct injection, flow injection, and UV digestion TOC analysis.
  • Working Range: can handle up to 30000 ppm with no sample dilution
  • 10-year Warranty on NDIR Detector: Ensuring long-term reliability.
  • Customised Solutions: Tailored for TOC/TNb measurements in various industries.
  • Accessories for analysing TN and solids are available

Multi N/C animation video - Analytik Jena GmbH

About the Multi N/C Series – Versatile TOC-/TNb Analyzers

The multi N/C Series from Analytik Jena represents a groundbreaking advancement in TOC/TNb Analysis. Designed with precision and efficiency in mind, these analysers are equipped with state-of-the-art technology, offering solutions that cater to a wide array of applications.

High Sensitivity and Accuracy: With the Focus Radiation NDIR Detector, the multi N/C Series ensures high sensitivity TOC analysis. This technology, coupled with the VITA Flow Management System, guarantees stable calibration and accurate results across various sample types.

Versatility Across Models: The series includes specialised models tailored to specific analytical needs. The multi N/C 2100S is designed for direct injection TOC analysis, the multi N/C 3100 offers flow injection capabilities, and the multi N/C UV HS is optimised for UV digestion. This range of options ensures that the multi N/C Series can adapt to diverse requirements in different industries.

The multiNC_2100S from Analytik Jena
The multiNC from Analytik Jena

Environmental and Industrial Applications: The multi N/C Series is not limited to one field of study. Its applications span across environmental monitoring, pharmaceutical quality control, oil & gas sector analysis, and more. The ability to determine TOC in solid waste, water, soil, and sediments makes it a versatile tool for both research and industrial purposes.

Long-Term Reliability: The long-term warranty on the NDIR Detector is a testament to the product’s durability and reliability. Analytik Jena’s commitment to quality is further emphasised by the High-Power Long-Life UV Reactor, ensuring complete oxidation and long-term performance.

Customised Solutions: Understanding that different sectors have unique analytical needs, the multi N/C Series offers customised solutions for TOC/TNb measurements. Whatever the analysis the multi N/C Series can meet those demands.

Cost-Efficient and User-Friendly: The multi N/C Series is not only about high-end technology but also about user convenience and cost efficiency. 

Innovation and Excellence: Analytik Jena’s multi N/C Series stands as a symbol of innovation and excellence in the field of TOC/TNb Analysis. With its cutting-edge technology, versatile design, and commitment to quality, it sets a new benchmark for analytical performance.

In conclusion, the multi N/C Series is more than just a set of TOC/TNb Analysers. It’s a comprehensive solution that brings together technology, versatility, reliability, and efficiency. Whether it’s environmental monitoring, industrial quality control, or specialised research, the multi N/C Series offers a tailored solution that’s built to meet the ever-evolving demands of modern analytical science. It’s not just a product; it’s a promise of excellence and innovation in the world of TOC/TNb Analysis.

People discussing infront of the multiNC from Analytik Jena

"Sophisticated Technologies for Your TOC/TNb Analysis."

Product FAQ's

The multi N/C Series is suitable for environmental, pharmaceutical, oil & gas, chemical, mining, power & energy industries.

Analytik Jena offers a 10-year warranty on both the NDIR Detector and combustion furnace.  

The multi N/C UV HS model is designed for UV Digestion TOC Analysis.

Yes, the multi N/C Series can determine TOC, TIC and TC in solid waste, water, soil, and sediments.

The Focus Radiation NDIR Detector ensures high sensitivity TOC analysis.

Contact Us Today

We take great pleasure in assisting you and ensuring you get a prompt response to your questions

Live chat opening hours Mon – Fri 9:15 to 16:30 (UK Time)

Request a Call Back

Please refer to our Privacy statement for information on how SciMed uses your details.
Back to Menu